48.893
Bearbeitungen
K |
K |
||
Zeile 10: | Zeile 10: | ||
! width="60" | [[Wasserdampfdiffusionswiderstand|µ]] <br /> [-] | ! width="60" | [[Wasserdampfdiffusionswiderstand|µ]] <br /> [-] | ||
! width="60" | [[sd-Wert|s<sub>d</sub>-Wert]] <br /> [m] | ! width="60" | [[sd-Wert|s<sub>d</sub>-Wert]] <br /> [m] | ||
! width="60" | [[Wasserdampfdiffusionswiderstand|µ]] <br /> <sub>Rechenwert</sub> <br /> [-] | ! width="60" | [[Wasserdampfdiffusionswiderstand|µ]] <br /> <sub>Rechenwert*</sub> <br /> [-] | ||
! width="60" | [[sd-Wert|s<sub>d</sub>-Wert]] <br /> <sub>Rechenwert</sub> <br /> [m] | ! width="60" | [[sd-Wert|s<sub>d</sub>-Wert]] <br /> <sub>Rechenwert*</sub> <br /> [m] | ||
! width="80" | [[sd-Wert|s<sub>d</sub>-Wert]] <br /> <sub>[[Feuchtevariabilität|feuchtevariabel]]</sub> <br /> [m] | ! width="80" | [[sd-Wert|s<sub>d</sub>-Wert]] <br /> <sub>[[Feuchtevariabilität|feuchtevariabel]]</sub> <br /> [m] | ||
| width="30" | | | width="30" | | ||
Zeile 31: | Zeile 31: | ||
{{Tab Sp2-10 center|[[SOLITEX MENTO 1000]]<br /> [[SOLITEX MENTO 1000 connect| ... MENTO 1000 connect]] |275|0,4|0,17|200|0,05|250|0,10|-|-}} | {{Tab Sp2-10 center|[[SOLITEX MENTO 1000]]<br /> [[SOLITEX MENTO 1000 connect| ... MENTO 1000 connect]] |275|0,4|0,17|200|0,05|250|0,10|-|-}} | ||
{{Tab Sp2-10 center|[[SOLITEX MENTO 3000]]<br /> [[SOLITEX MENTO 3000 connect| ... MENTO 3000 connect]] | {{Tab Sp2-10 center|[[SOLITEX MENTO 3000]]<br /> [[SOLITEX MENTO 3000 connect| ... MENTO 3000 connect]] | ||
|280|0,5|0,17|200|< 0,10|200|0,10|-|-}} | |280|0,5|0,17|< 200|< 0,10|200|0,10|-|-}} | ||
{{Tab Sp2-10 center|[[SOLITEX MENTO 5000]]<br /> [[SOLITEX MENTO 5000 connect| ... MENTO 5000 connect]] | {{Tab Sp2-10 center|[[SOLITEX MENTO 5000]]<br /> [[SOLITEX MENTO 5000 connect| ... MENTO 5000 connect]] | ||
|300|0,7|0,17|143|< 0,10|143|0,10|-|-}} | |300|0,7|0,17|< 143|< 0,10|143|0,10|-|-}} | ||
{{Tab Sp2-10 center|[[SOLITEX MENTO PLUS]]<br /> [[SOLITEX MENTO PLUS connect| ... MENTO PLUS connect]] | {{Tab Sp2-10 center|[[SOLITEX MENTO PLUS]]<br /> [[SOLITEX MENTO PLUS connect| ... MENTO PLUS connect]] | ||
|285|0,6|0,17|167|< 0,10|167|0,10|-|-}} | |285|0,6|0,17|< 167|< 0,10|167|0,10|-|-}} | ||
{{Tab Sp2-10 center|[[SOLITEX UD]]<br /> [[SOLITEX UD connect]]|280|0,50|0,17|160|< 0,08|200|0,10|0,02 <sub>[[Feuchtevariabilität|feuchtevariabel]]</sub>|-}} | {{Tab Sp2-10 center|[[SOLITEX UD]]<br /> [[SOLITEX UD connect]]|280|0,50|0,17|160|< 0,08|200|0,10|0,02 <sub>[[Feuchtevariabilität|feuchtevariabel]]</sub>|-}} | ||
{{Tab Sp2-10 center|[[SOLITEX PLUS]]<br /> [[SOLITEX PLUS connect]]|310|0,55|0,17|145|< 0,08|182|0,10|0,02 <sub>[[Feuchtevariabilität|feuchtevariabel]]</sub>|-}} | {{Tab Sp2-10 center|[[SOLITEX PLUS]]<br /> [[SOLITEX PLUS connect]]|310|0,55|0,17|145|< 0,08|182|0,10|0,02 <sub>[[Feuchtevariabilität|feuchtevariabel]]</sub>|-}} | ||
Zeile 41: | Zeile 41: | ||
{{Tab Sp2-10 center|[[SOLITEX WA]]|222|0,45|0,17|22|0,01|222|0,10|-|-}} | {{Tab Sp2-10 center|[[SOLITEX WA]]|222|0,45|0,17|22|0,01|222|0,10|-|-}} | ||
|} | |} | ||
::: *) Nach [[DIN EN ISO 12572]] und [[DIN 4108|DIN 4108-3]] ist für [[sd-Wert|s<sub>d</sub>-Werte]] < 0,10 m der Rechenwert 0,10 m einzusetzen. | |||
{| | {| | ||
| width="70" | '''''Legende:'''''|| Alle Bahnen: ||[[Wärmekapazität|Spezifische Wärmekapazität]]: 1 J/(kg x k) | | width="70" | '''''Legende:''''' || Alle Bahnen: ||[[Wärmekapazität|Spezifische Wärmekapazität]]: 1 J/(kg x k) | ||
|- | |- | ||
| || SHI: || entspricht [[Sentinel-Haus-Institut]] Anforderungen an [[Wohngesundheit|wohngesunde]] Bauprojekte, gem. Prüfbericht-Nr 21320-1-3 vom [[eco-INSTITUT]]. | | || SHI: || entspricht [[Sentinel-Haus-Institut]] Anforderungen an [[Wohngesundheit|wohngesunde]] Bauprojekte, gem. Prüfbericht-Nr 21320-1-3 vom [[eco-INSTITUT]]. |