Zeile 11: | Zeile 11: | ||
! width="60" | [[Wasserdampfdiffusionswiderstand|µ]] <br /> [-] | ! width="60" | [[Wasserdampfdiffusionswiderstand|µ]] <br /> [-] | ||
! width="60" | [[sd-Wert|s<sub>d</sub>-Wert]] <br /> [m] | ! width="60" | [[sd-Wert|s<sub>d</sub>-Wert]] <br /> [m] | ||
! width="60" | [[Wasserdampfdiffusionswiderstand|µ]] <br /> <sub>Rechenwert</sub> <br /> [-] | |||
! width="60" | [[sd-Wert|s<sub>d</sub>-Wert]] <br /> <sub>Rechenwert</sub> <br /> [m] | ! width="60" | [[sd-Wert|s<sub>d</sub>-Wert]] <br /> <sub>Rechenwert</sub> <br /> [m] | ||
! width="80" | [[sd-Wert|s<sub>d</sub>-Wert]] <br /> <sub>[[Feuchtevariabilität|feuchtevariabel]]</sub> <br /> [m] | ! width="80" | [[sd-Wert|s<sub>d</sub>-Wert]] <br /> <sub>[[Feuchtevariabilität|feuchtevariabel]]</sub> <br /> [m] | ||
|- | |- | ||
{{TabF2}} | {{TabF2}} | ||
|colspan="6"| '''Luftdichtung innen''' || align="center"| <sub>nach <br />[[DIN 4108]]-3</sub>|| align="center"| <sub>'''Nicht''' für das <br />[[Glaser-Verfahren]]</sub> | |colspan="6"| '''Luftdichtung innen''' || colspan="2" align="center"| <sub>nach <br />[[DIN 4108]]-3</sub>|| align="center"| <sub>'''Nicht''' für das <br />[[Glaser-Verfahren]]</sub> | ||
|- | |- | ||
{{Tab Sp2- | {{Tab Sp2-9 center|[[DB]]|600|0,23|0,13|10.000|2,30|10.000|2,30|0,60 - 4,00}} | ||
{{Tab Sp2- | {{Tab Sp2-9 center|[[DB+]]|625|0,23|0,13|10.000|2,30|10.000|2,30|0,60 - 4,00}} | ||
{{Tab Sp2- | {{Tab Sp2-9 center|[[INTELLO]]|500|0,20|0,17|37.500|7,50|37.500|7,50|0,25 - >10,00}} | ||
{{Tab Sp2- | {{Tab Sp2-9 center|[[INTELLO PLUS]]|625|0,20|0,17|37.500|7,50|37.500|7,50|0,25 - >10,00}} | ||
{{Tab Sp2- | {{Tab Sp2-9 center|[[INTESANA]]<br /> [[INTESANA connect]]|310|0,45|0,17|16.700|7,50|16.700|7,50|0,25 - >10,00}} | ||
{{Tab Sp2- | {{Tab Sp2-9 center|[[DA]]<br /> [[DA connect]]|320|0,46|0,17|5.000|2,30|5.000|2,30|-}} | ||
{{Tab Sp2- | {{Tab Sp2-9 center|[[DASATOP]]|280|0,25|0,17|6.400|1,60|6.400|1,60|0,05 - 2,00}} | ||
{{Tab Sp2- | {{Tab Sp2-9 center|[[SANTA DT]]<br /> [[SANTA UT]]|600|0,40|0,13|5.750|2,30|5.750|2,30|-}} | ||
{{Tab Sp2- | {{Tab Sp2-9 center|[[RB]]|600|0,30|0,13|100|0,03|333|0,10|-}} | ||
|- | |- | ||
{{TabF2}} | {{TabF2}} | ||
|colspan=" | |colspan="9"| '''Winddichtung außen''' | ||
|- | |- | ||
{{Tab Sp2- | {{Tab Sp2-9 center|[[SOLITEX MENTO]]<br /> [[SOLITEX MENTO connect]]|275|0,4|0,17|200|0,05|250|0,10|-}} | ||
{{Tab Sp2- | {{Tab Sp2-9 center|[[SOLITEX UD]]<br /> [[SOLITEX UD connect]]|280|0,50|0,17|160|< 0,08|200|0,10|0,02 <sub>[[Feuchtevariabilität|feuchtevariabel]]</sub>}} | ||
{{Tab Sp2- | {{Tab Sp2-9 center|[[SOLITEX PLUS]]<br /> [[SOLITEX PLUS connect]]|310|0,55|0,17|145|< 0,08|182|0,10|0,02 <sub>[[Feuchtevariabilität|feuchtevariabel]]</sub>}} | ||
{{Tab Sp2- | {{Tab Sp2-9 center|[[SOLITEX UM connect]]|63|8|0,17|10|< 0,08|12,5|0,10|0,02 <sub>[[Feuchtevariabilität|feuchtevariabel]]</sub>}} | ||
{{Tab Sp2- | {{Tab Sp2-9 center|[[SOLITEX WA]]|222|0,45|0,17|22|0,01|222|0,10|-}} | ||
|} | |} | ||
Für alle Bahnen gilt: [[Wärmekapazität|Spezifische Wärmekapazität]]: 1 J/(kg x k) | Für alle Bahnen gilt: [[Wärmekapazität|Spezifische Wärmekapazität]]: 1 J/(kg x k) |