{{{TabH1/2}} Beispiele: Bemessungswerte der Dampdiffusionswiderstandszahlen | {{{TabH1/2}} Beispiele: Bemessungswerte der Dampdiffusionswiderstandszahlen | ||
|- class="hintergrundfarbe2" | |- class="hintergrundfarbe2" | ||
! width="150" | Material | ! width="150" | Material | ||
Zeile 19: | Zeile 19: | ||
µ · s [m] | µ · s [m] | ||
|- | |- | ||
| [[Gipskartonplatte|Gipskarton | | [[Gipskartonplatte|Gipskarton]] | ||
| align="center" | '''8''' | | align="center" | '''8'''<sup>1)</sup> | ||
| align="center" | 0,0125 | | align="center" | 0,0125 | ||
| align="center" | 0,10 | | align="center" | 0,10 | ||
|- | |||
| [[Gipsfaserplatte|Gipsfaser]] | |||
| align="center" | '''13'''<sup>1)</sup> | |||
| align="center" | 0,0125 | |||
| align="center" | 0,16 | |||
|- | |||
| Kalkputz | |||
| align="center" | '''15 / 35''' | |||
| align="center" | 0,0150 | |||
| align="center" | 0,23 / 0,53 | |||
|- | |- | ||
| Fichte, Kiefer, Tanne | | valign="top" | Fichte, Kiefer, Tanne <br /> - effektiv [[Feuchtevariabilität|feuchtevariabel]] | ||
| align=" | | align="right" | '''40'''<sup>1)</sup> <br /> '''12 - 15''' <small>b. 60% Holzfeuchte</small> <br /> '''200''' <small>b. 10% Holzfeuchte</small> | ||
| align="center" | 0,0240 | | align="center" | 0,0240 | ||
| align="center" | 0,96 | | align="center" | 0,96 <br /> 0,29 - 0,36 <br /> 4,80 | ||
|- | |- | ||
| [[Sperrholz]] n. [[DIN 68705]] | | [[Sperrholz]] n. [[DIN 68705]] | ||
| align="center" | '''50 / 400''' | | align="center" | '''50 / 400'''<sup>1)</sup> | ||
| align="center" | 0,0200 | | align="center" | 0,0200 | ||
| align="center" | 1,00 / 8,00 | | align="center" | 1,00 / 8,00 | ||
|- | |- | ||
| Beton | | Beton | ||
| align="center" | '''70 / 150''' | | align="center" | '''70 / 150'''<sup>1)</sup> | ||
| align="center" | 0,1600 | | align="center" | 0,1600 | ||
| align="center" | 11,20 / 24,00 | | align="center" | 11,20 / 24,00 | ||
|- | |- | ||
| Vollklinker 2200 kg/m³ | | Vollklinker 2200 kg/m³ | ||
| align="center" | '''50 / 100''' | | align="center" | '''50 / 100'''<sup>1)</sup> | ||
| align="center" | 0,2400 | | align="center" | 0,2400 | ||
| align="center" | 12,00 / 24,00 | | align="center" | 12,00 / 24,00 | ||
Zeile 54: | Zeile 64: | ||
| align="center" | 50,00 | | align="center" | 50,00 | ||
|- | |- | ||
| Bitumenbahn | | Bitumenbahn | ||
| align="center" | '''80.000''' | | align="center" | '''80.000''' | ||
| align="center" | 0,0030 | | align="center" | 0,0030 | ||
| align="center" | 240,00 | | align="center" | 240,00 | ||
|- | |- | ||
| Aluminiumlegierungen | | Aluminiumlegierungen | ||
| align="center" | <small>praktisch dampfdicht ab 50 µm Dicke <br /> häufig verwendeter Rechenwert: </small> <br /> '''999999''' | | align="center" | <small>praktisch dampfdicht ab 50 µm Dicke <br /> häufig verwendeter Rechenwert: </small> <br /> '''999999'''<sup>1)</sup> | ||
| align="center" | 0,0005 | | align="center" | 0,0005 | ||
| align="center" | 500,00 | | align="center" | 500,00 | ||
|- | |||
| colspan="4" | <sup>1)</sup> Dampdiffusionswiderstandszahlen nach [[DIN 4108-4]] | |||
|} | |} | ||
<div style="clear: both; visibility: hidden;">dient Zeilenumbruch</div> | <div style="clear: both; visibility: hidden;">dient Zeilenumbruch</div> |