Technische Daten - Übersicht: Unterschied zwischen den Versionen

Zur Navigation springen Zur Suche springen
K
Zeile 33: Zeile 33:
|-
|-
{{Tab Sp2-11 center|[[SOLITEX MENTO 1000]]<br /> [[SOLITEX MENTO 1000 connect| &nbsp; ... &nbsp; 1000 connect]]  
{{Tab Sp2-11 center|[[SOLITEX MENTO 1000]]<br /> [[SOLITEX MENTO 1000 connect| &nbsp; ... &nbsp; 1000 connect]]  
|288|115 <small>&plusmn;5</small>|0,40 <small>&plusmn;0,05</small>|0,17|125|0,05 <small>&plusmn;0,02</small>|250|0,10|-|-}}
|288|115 <small>&plusmn;5</small>|0,40 <small>&plusmn;0,05</small>|0,17|125|0,05 <small>&plusmn;0,02</small>|250|0,10|-|<small>CE, [[Luftdichtheit|Ld1]], W1, Srt <br /> [[USB-A]], [[UDB-B]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K2]] </small>}}
 
{{Tab Sp2-11 center|[[SOLITEX MENTO 3000]]<br /> [[SOLITEX MENTO 3000 connect| &nbsp; ... &nbsp; 3000 connect]]  
{{Tab Sp2-11 center|[[SOLITEX MENTO 3000]]<br /> [[SOLITEX MENTO 3000 connect| &nbsp; ... &nbsp; 3000 connect]]  
|333|150 <small>&plusmn;5</small>|0,45 <small>&plusmn;0,05</small>|0,17|110|0,05 <small>&plusmn;0,02</small>|220|0,10|-|-}}
|333|150 <small>&plusmn;5</small>|0,45 <small>&plusmn;0,05</small>|0,17|110|0,05 <small>&plusmn;0,02</small>|220|0,10|-|<small>CE, [[Luftdichtheit|Ld1]], W1, Srt <br /> [[Unterdach|UD1]], [[USB-A]], [[UDB-A]], [[Behelfsdeckung|Bhd]], [[Durchsturzsicherheit|D]], [[Kaltbiegeverhalten|K2]], ZVDH </small>}}
 
{{Tab Sp2-11 center|[[SOLITEX MENTO 5000]]<br /> [[SOLITEX MENTO 5000 connect| &nbsp; ... &nbsp; 5000 connect]]  
{{Tab Sp2-11 center|[[SOLITEX MENTO 5000]]<br /> [[SOLITEX MENTO 5000 connect| &nbsp; ... &nbsp; 5000 connect]]  
|307|215 <small>&plusmn;5</small>|0,70 <small>&plusmn;0,10</small>|0,17|71|0,05 <small>&plusmn;0,02</small>|143|0,10|-|-}}
|307|215 <small>&plusmn;5</small>|0,70 <small>&plusmn;0,10</small>|0,17|71|0,05 <small>&plusmn;0,02</small>|143|0,10|-|<small>CE, [[Luftdichtheit|Ld1]],  W1, Srt <br /> [[Unterdach|UD1]], [[USB-A]], [[UDB-A]], [[Behelfsdeckung|Bhd]], [[Durchsturzsicherheit|D]], [[Kaltbiegeverhalten|K2]], ZVDH </small>}}
 
{{Tab Sp2-11 center|[[SOLITEX MENTO PLUS]]<br /> [[SOLITEX MENTO PLUS connect| &nbsp; ...&nbsp; PLUS connect]]  
{{Tab Sp2-11 center|[[SOLITEX MENTO PLUS]]<br /> [[SOLITEX MENTO PLUS connect| &nbsp; ...&nbsp; PLUS connect]]  
|292|175 <small>&plusmn;5</small>|0,60 <small>&plusmn;0,10</small>|0,17|83|0,05 <small>&plusmn;0,02</small>|167|0,10|-|-}}
|292|175 <small>&plusmn;5</small>|0,60 <small>&plusmn;0,10</small>|0,17|83|0,05 <small>&plusmn;0,02</small>|167|0,10|-|<small>CE, [[Luftdichtheit|Ld1]], W1, Srt <br /> [[USB-A]], [[UDB-A]], [[Behelfsdeckung|Bhd]], [[Durchsturzsicherheit|D]], [[Kaltbiegeverhalten|K2]] </small>}}
 
{{Tab Sp2-11 center|[[SOLITEX UD]]<br /> [[SOLITEX UD connect]]
{{Tab Sp2-11 center|[[SOLITEX UD]]<br /> [[SOLITEX UD connect]]
|290|145 <small>&plusmn;5</small>|0,50 <small>&plusmn;0,05</small>|0,17|160|0,06 <small>&plusmn;0,02</small>|200|0,10|0,02 <sup>[[Feuchtevariabilität|feuchtevariabel]]</sup>|-}}
|290|145 <small>&plusmn;5</small>|0,50 <small>&plusmn;0,05</small>|0,17|160|0,06 <small>&plusmn;0,02</small>|200|0,10|0,02 <sup>[[Feuchtevariabilität|feuchtevariabel]]</sup>|<small>CE, [[Luftdichtheit|Ld1]], W1, Srt <br /> [[Unterdach|UD1]], [[USB-A]], [[UDB-A]], [[Behelfsdeckung|Bhd]], [[Durchsturzsicherheit|D]], [[Kaltbiegeverhalten|K2]] </small>}}
 
{{Tab Sp2-11 center|[[SOLITEX PLUS]]<br /> [[SOLITEX PLUS connect]]
{{Tab Sp2-11 center|[[SOLITEX PLUS]]<br /> [[SOLITEX PLUS connect]]
|310|170 <small>&plusmn;5</small>|0,55 <small>&plusmn;0,10</small>|0,17|145|0,06 <small>&plusmn;0,02</small>|182|0,10|0,02 <sup>[[Feuchtevariabilität|feuchtevariabel]]</sup>|-}}
|310|170 <small>&plusmn;5</small>|0,55 <small>&plusmn;0,10</small>|0,17|145|0,06 <small>&plusmn;0,02</small>|182|0,10|0,02 <sup>[[Feuchtevariabilität|feuchtevariabel]]</sup>|<small>CE, [[Luftdichtheit|Ld1]], W1, Srt <br /> [[USB-A]], [[UDB-A]], [[Behelfsdeckung|Bhd]], [[Durchsturzsicherheit|D]], [[Kaltbiegeverhalten|K2]], iab, bba </small>}}
 
{{Tab Sp2-11 center|[[SOLITEX UM connect]]
{{Tab Sp2-11 center|[[SOLITEX UM connect]]
|53|420 <small>&plusmn;10</small>|8,00 <small>&plusmn;0,5</small>|0,17|6|0,05 <small>&plusmn;0,02</small>|12,5|0,10|-|-}}
|53|420 <small>&plusmn;10</small>|8,00 <small>&plusmn;0,5</small>|0,17|6|0,05 <small>&plusmn;0,02</small>|12,5|0,10|-|<small>CE, [[Luftdichtheit|Ld1]], W1 <br /> [[Kaltbiegeverhalten|K2]], ZVDH</small>}}
 
{{Tab Sp2-11 center|[[SOLITEX WELDANO]] & [[SOLITEX WELDANO-S|...-S]]
{{Tab Sp2-11 center|[[SOLITEX WELDANO]] & [[SOLITEX WELDANO-S|...-S]]
|385|310 <small>&plusmn;15</small>|0,8 <small>&plusmn;0,05</small>|0,17|225|0,18 <small>&plusmn;0,04</small>|225|0,18|-|-}}
|385|310 <small>&plusmn;15</small>|0,8 <small>&plusmn;0,05</small>|0,17|225|0,18 <small>&plusmn;0,04</small>|225|0,18|-|<small>CE, [[Luftdichtheit|Ld1]], W1 <br /> [[Unterdach|UD2]], [[UDB-A]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K1]] </small>}}
 
{{Tab Sp2-11 center|[[SOLITEX FRONTA PENTA]] <br /> [[SOLITEX FRONTA PENTA connect|&nbsp; ... &nbsp; PENTA connect]]
{{Tab Sp2-11 center|[[SOLITEX FRONTA PENTA]] <br /> [[SOLITEX FRONTA PENTA connect|&nbsp; ... &nbsp; PENTA connect]]
|255|280 <small>&plusmn;15</small>|1,1 <small>&plusmn;0,2</small>|0,17|185|0,20 <small>&plusmn;0,05</small>|185|0,20|-|-}}
|255|280 <small>&plusmn;15</small>|1,1 <small>&plusmn;0,2</small>|0,17|185|0,20 <small>&plusmn;0,05</small>|185|0,20|-|<small>CE, [[Luftdichtheit|Ld1]], W1 <br /> [[Kaltbiegeverhalten|K2]] </small>}}
 
{{Tab Sp2-11 center|[[SOLITEX FRONTA QUATTRO]] <br /> [[SOLITEX FRONTA QUATTRO connect|&nbsp; ... &nbsp; QUATTRO connect]]
{{Tab Sp2-11 center|[[SOLITEX FRONTA QUATTRO]] <br /> [[SOLITEX FRONTA QUATTRO connect|&nbsp; ... &nbsp; QUATTRO connect]]
|300|180 <small>&plusmn;5</small>|0,60 <small>&plusmn;0,10</small>|0,17|80|0,05 <small>&plusmn;0,02</small>|167|0,10|-|-}}
|300|180 <small>&plusmn;5</small>|0,60 <small>&plusmn;0,10</small>|0,17|80|0,05 <small>&plusmn;0,02</small>|167|0,10|-|<small>CE, [[Luftdichtheit|Ld1]], W1 <br /> [[Kaltbiegeverhalten|K2]], ZVDH </small>}}
 
{{Tab Sp2-11 center|[[SOLITEX FRONTA WA]] <br /> [[SOLITEX FRONTA WA connect|&nbsp; ... &nbsp; WA connect]]
{{Tab Sp2-11 center|[[SOLITEX FRONTA WA]] <br /> [[SOLITEX FRONTA WA connect|&nbsp; ... &nbsp; WA connect]]
|222|100 <small>&plusmn;5</small>|0,45 <small>&plusmn;0,05</small>|0,17|110|0,05 <small>&plusmn;0,02</small> |222|0,10|-|-}}
|222|100 <small>&plusmn;5</small>|0,45 <small>&plusmn;0,05</small>|0,17|110|0,05 <small>&plusmn;0,02</small> |222|0,10|-|<small>CE, [[Luftdichtheit|Ld1]], W1 <br /> [[Kaltbiegeverhalten|K2]], ZVDH</small>}}
 
{{Tab Sp2-11 center|[[SOLITEX WB]]
{{Tab Sp2-11 center|[[SOLITEX WB]]
|222|100|0,45|0,17|110|0,05|222|0,10|-|-}}
|222|100|0,45|0,17|110|0,05|222|0,10|-|<small>W2 </small>}}
 
{{Tab Sp2-11 center|[[SOLITEX FRONTA HUMIDA]]
{{Tab Sp2-11 center|[[SOLITEX FRONTA HUMIDA]]
|288|115 <small>&plusmn;5</small>|0,40 <small>&plusmn;0,05</small>|0,17|1.250|0,50 <small>&plusmn;0,10</small>|1.250|0,5|-|-}}
|288|115 <small>&plusmn;5</small>|0,40 <small>&plusmn;0,05</small>|0,17|1.250|0,50 <small>&plusmn;0,10</small>|1.250|0,5|-|<small>CE, W1 <br /> [[Kaltbiegeverhalten|K2]], ZVDH </small>}}
|}  
|}  
::: *) Nach [[DIN EN ISO 12572]] und [[DIN 4108|DIN 4108-3]] ist für [[sd-Wert|s<sub>d</sub>-Werte]] < 0,10 m der Rechenwert 0,10 m einzusetzen.
::: *) Nach [[DIN EN ISO 12572]] und [[DIN 4108|DIN 4108-3]] ist für [[sd-Wert|s<sub>d</sub>-Werte]] < 0,10 m der Rechenwert 0,10 m einzusetzen.