Technische Daten - Übersicht: Unterschied zwischen den Versionen

Zur Navigation springen Zur Suche springen
K
Zeile 34: Zeile 34:


{{Tab Sp2-11 center|[[SOLITEX ADHERO 3000]]  
{{Tab Sp2-11 center|[[SOLITEX ADHERO 3000]]  
|343|240|0,70|0,04|570|0,4|570|0,4|0,3 - 0,8|<small>CE, HW5/EN 13583, [[Luftdichtheit|Ld1]], W1, Srt <br />  [[UDB-A]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K2]], [[QNG]] </small>}}
|343|240|0,7|0,04|570|0,4|570|0,4|0,3 - 0,8|<small>CE, HW5/EN 13583, [[Luftdichtheit|Ld1]], W1, Srt <br />  [[UDB-A]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K2]], [[QNG]] </small>}}


{{Tab Sp2-11 center|[[SOLITEX ADHERO VISTO]]  
{{Tab Sp2-11 center|[[SOLITEX ADHERO VISTO]]  
Zeile 40: Zeile 40:


{{Tab Sp2-11 center|[[SOLITEX MENTO 1000]]<br /> [[SOLITEX MENTO 1000 connect| &nbsp; ... &nbsp; 1000 connect]]  
{{Tab Sp2-11 center|[[SOLITEX MENTO 1000]]<br /> [[SOLITEX MENTO 1000 connect| &nbsp; ... &nbsp; 1000 connect]]  
|288|115|0,40|0,04|125|0,05|250|0,10|-|<small>CE, [[Luftdichtheit|Ld1]], W1, Srt <br /> [[USB-A]], [[UDB-B]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K2]], [[QNG]] </small>}}
|288|115|0,4|0,04|125|0,05|250|0,10|-|<small>CE, [[Luftdichtheit|Ld1]], W1, Srt <br /> [[USB-A]], [[UDB-B]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K2]], [[QNG]] </small>}}


{{Tab Sp2-11 center|[[SOLITEX MENTO 3000]]<br /> [[SOLITEX MENTO 3000 connect| &nbsp; ... &nbsp; 3000 connect]]  
{{Tab Sp2-11 center|[[SOLITEX MENTO 3000]]<br /> [[SOLITEX MENTO 3000 connect| &nbsp; ... &nbsp; 3000 connect]]  
Zeile 46: Zeile 46:


{{Tab Sp2-11 center|[[SOLITEX MENTO 5000]]<br /> [[SOLITEX MENTO 5000 connect| &nbsp; ... &nbsp; 5000 connect]]  
{{Tab Sp2-11 center|[[SOLITEX MENTO 5000]]<br /> [[SOLITEX MENTO 5000 connect| &nbsp; ... &nbsp; 5000 connect]]  
|307|215|0,70|0,04|71|0,05|143|0,10|-|<small>CE, HW5, [[Luftdichtheit|Ld1]],  W1, Srt <br /> [[Unterdach|UD1]], [[USB-A]], [[UDB-A]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K2]], [[QNG]], ZVDH </small>}}
|307|215|0,7|0,04|71|0,05|143|0,10|-|<small>CE, HW5, [[Luftdichtheit|Ld1]],  W1, Srt <br /> [[Unterdach|UD1]], [[USB-A]], [[UDB-A]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K2]], [[QNG]], ZVDH </small>}}


{{Tab Sp2-11 center|[[SOLITEX MENTO PLUS]]<br /> [[SOLITEX MENTO PLUS connect| &nbsp; ...&nbsp; PLUS connect]]  
{{Tab Sp2-11 center|[[SOLITEX MENTO PLUS]]<br /> [[SOLITEX MENTO PLUS connect| &nbsp; ...&nbsp; PLUS connect]]  
|292|175|0,60|0,04|83|0,05|167|0,10|-|<small>CE, HW5, [[Luftdichtheit|Ld1]], W1, Srt <br /> [[USB-A]], [[UDB-A]], [[Behelfsdeckung|Bhd]], [[Durchsturzsicherheit|D1]], [[Kaltbiegeverhalten|K2]] </small>}}
|292|175|0,6|0,04|83|0,05|167|0,10|-|<small>CE, HW5, [[Luftdichtheit|Ld1]], W1, Srt <br /> [[USB-A]], [[UDB-A]], [[Behelfsdeckung|Bhd]], [[Durchsturzsicherheit|D1]], [[Kaltbiegeverhalten|K2]] </small>}}


{{Tab Sp2-11 center|[[SOLITEX MENTO ULTRA]]<br /> [[SOLITEX MENTO ULTRA connect| &nbsp; ...&nbsp;ULTRA connect]]  
{{Tab Sp2-11 center|[[SOLITEX MENTO ULTRA]]<br /> [[SOLITEX MENTO ULTRA connect| &nbsp; ...&nbsp;ULTRA connect]]  
|222|200|0,90|0,04|167|0,15|111|0,10|-|<small>CE, HW5, [[Luftdichtheit|Ld2]], W1, Srt <br /> [[USB-A]], [[UDB-A]], [[Behelfsdeckung|Bhd]], [[Durchsturzsicherheit|D2]], [[Kaltbiegeverhalten|K2]] </small>}}
|222|200|0,9|0,04|167|0,15|111|0,10|-|<small>CE, HW5, [[Luftdichtheit|Ld2]], W1, Srt <br /> [[USB-A]], [[UDB-A]], [[Behelfsdeckung|Bhd]], [[Durchsturzsicherheit|D2]], [[Kaltbiegeverhalten|K2]] </small>}}
 
{{Tab Sp2-11 center|[[SOLITEX QUANTHO 3000 connect]]
|330|230|0,7|0,04|230|0,16|230|0,16|-|<small>CE, EN 13583/HW5, [[Luftdichtheit|Ld1]], W1, Srt, [[AgBB]] <br /> [[Unterdach|UD1]], [[USB-A]], [[UDB-A]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K2]] </small>}}


{{Tab Sp2-11 center|[[SOLITEX UD]]<br /> [[SOLITEX UD connect]]
{{Tab Sp2-11 center|[[SOLITEX UD]]<br /> [[SOLITEX UD connect]]
|290|145|0,50|0,04|160|0,06|200|0,10| 0,01 <sup>[[Feuchtevariabilität|feuchtevariabel]]</sup>|<small>CE, [[Luftdichtheit|Ld1]], W1, Srt <br /> [[Unterdach|UD1]], [[USB-A]], [[UDB-A]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K2]] </small>}}
|290|145|0,5|0,04|160|0,06|200|0,10| 0,01 <sup>[[Feuchtevariabilität|feuchtevariabel]]</sup>|<small>CE, [[Luftdichtheit|Ld1]], W1, Srt <br /> [[Unterdach|UD1]], [[USB-A]], [[UDB-A]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K2]] </small>}}


{{Tab Sp2-11 center|[[SOLITEX PLUS]]<br /> [[SOLITEX PLUS connect]]
{{Tab Sp2-11 center|[[SOLITEX PLUS]]<br /> [[SOLITEX PLUS connect]]
Zeile 61: Zeile 64:


{{Tab Sp2-11 center|[[SOLITEX UM connect]]
{{Tab Sp2-11 center|[[SOLITEX UM connect]]
|53|420|8,00|0,04|6|0,05|12,5|0,10|-|<small>CE, [[Luftdichtheit|Ld1]], W1 , [[Kaltbiegeverhalten|K2]], ZVDH</small>}}
|53|420|8|0,04|6|0,05|12,5|0,10|-|<small>CE, [[Luftdichtheit|Ld1]], W1 , [[Kaltbiegeverhalten|K2]], ZVDH</small>}}


{{Tab Sp2-11 center|[[SOLITEX WELDANO]] & [[SOLITEX WELDANO-S|...-S]]
{{Tab Sp2-11 center|[[SOLITEX WELDANO]] & [[SOLITEX WELDANO-S|...-S]]
Zeile 73: Zeile 76:


{{Tab Sp2-11 center|[[SOLITEX FRONTA QUATTRO FB]] <br /> [[SOLITEX FRONTA QUATTRO FB connect|&nbsp; ... &nbsp; connect]]
{{Tab Sp2-11 center|[[SOLITEX FRONTA QUATTRO FB]] <br /> [[SOLITEX FRONTA QUATTRO FB connect|&nbsp; ... &nbsp; connect]]
|290|145|0,50|0,04|160|0,08|200|0,10|-|<small>CE, [[Luftdichtheit|Ld1]], W1, [[Kaltbiegeverhalten|K2]] </small>}}
|290|145|0,5|0,04|160|0,08|200|0,10|-|<small>CE, [[Luftdichtheit|Ld1]], W1, [[Kaltbiegeverhalten|K2]] </small>}}


{{Tab Sp2-11 center|[[SOLITEX FRONTA QUATTRO]] <br /> [[SOLITEX FRONTA QUATTRO connect|&nbsp; ... &nbsp; connect]]
{{Tab Sp2-11 center|[[SOLITEX FRONTA QUATTRO]] <br /> [[SOLITEX FRONTA QUATTRO connect|&nbsp; ... &nbsp; connect]]
|300|180|0,60|0,04|80|0,05|167|0,10|-|<small>CE, [[Luftdichtheit|Ld1]], W1, [[Kaltbiegeverhalten|K2]], [[QNG]], ZVDH </small>}}
|300|180|0,6|0,04|80|0,05|167|0,10|-|<small>CE, [[Luftdichtheit|Ld1]], W1, [[Kaltbiegeverhalten|K2]], [[QNG]], ZVDH </small>}}


{{Tab Sp2-11 center|[[SOLITEX FRONTA WA]] <br /> [[SOLITEX FRONTA WA connect|&nbsp; ... &nbsp; connect]]
{{Tab Sp2-11 center|[[SOLITEX FRONTA WA]] <br /> [[SOLITEX FRONTA WA connect|&nbsp; ... &nbsp; connect]]
Zeile 82: Zeile 85:


{{Tab Sp2-11 center|[[SOLITEX FRONTA HUMIDA]]
{{Tab Sp2-11 center|[[SOLITEX FRONTA HUMIDA]]
|288|115|0,40|0,04|1.250|0,50|1.250|0,5|-|<small>CE, W1, [[Kaltbiegeverhalten|K2]], ZVDH </small>}}
|288|115|0,4|0,04|1.250|0,50|1.250|0,5|-|<small>CE, W1, [[Kaltbiegeverhalten|K2]], ZVDH </small>}}
|}  
|}  
::: *) Nach [[DIN EN ISO 12572]] und [[DIN 4108|DIN 4108-3]] ist für [[sd-Wert|s<sub>d</sub>-Werte]] < 0,10 m der Rechenwert 0,10 m einzusetzen.
::: *) Nach [[DIN EN ISO 12572]] und [[DIN 4108|DIN 4108-3]] ist für [[sd-Wert|s<sub>d</sub>-Werte]] < 0,10 m der Rechenwert 0,10 m einzusetzen.

Navigationsmenü