48.791
Bearbeitungen
K (→Weitere Werte) |
|||
Zeile 24: | Zeile 24: | ||
{{Tab Sp2-11 center|[[DA]] & [[DA connect|... connect]]|290|130|0,45|0,04|5.000|2,30|5.000|2,30|-|<sup>CE, [[Luftdichtheit|Ld2]], W1, [[Wassersäule|Ws]], [[AgBB]], [[QNG]], ZVDH</sup> }} | {{Tab Sp2-11 center|[[DA]] & [[DA connect|... connect]]|290|130|0,45|0,04|5.000|2,30|5.000|2,30|-|<sup>CE, [[Luftdichtheit|Ld2]], W1, [[Wassersäule|Ws]], [[AgBB]], [[QNG]], ZVDH</sup> }} | ||
{{Tab Sp2-11 center|[[DASATOP]]|360|90|0,25|0,04|6.400|1,60|6.400|1,60|0,05 - 2,00|<sup>CE, [[Luftdichtheit|Ld2]], [[AgBB]], [[QNG]], ZVDH</sup>}} | {{Tab Sp2-11 center|[[DASATOP]]|360|90|0,25|0,04|6.400|1,60|6.400|1,60|0,05 - 2,00|<sup>CE, [[Luftdichtheit|Ld2]], [[AgBB]], [[QNG]], ZVDH</sup>}} | ||
{{Tab Sp2-11 center|[[DASAPLANO 0,01 connect|DASAPLANO 0,01<small> connect</small>]]|280|145|0,50|0,04|20|-|200|0,10|0,01 <sup> [[Feuchtevariabilität|feuchtevariabel]]</sup>|<small>CE, [[Luftdichtheit|Ld2]], W1, Srt, [[AgBB]] <br /> [[USB | {{Tab Sp2-11 center|[[DASAPLANO 0,01 connect|DASAPLANO 0,01<small> connect</small>]]|280|145|0,50|0,04|20|-|200|0,10|0,01 <sup> [[Feuchtevariabilität|feuchtevariabel]]</sup>|<small>CE, [[Luftdichtheit|Ld2]], W1, Srt, [[AgBB]] <br /> [[USB]], [[UDB]], [[Durchsturzsicherheit|D]], [[QNG]]</small> }} | ||
{{Tab Sp2-11 center|[[RB]]|450|45|0,10|0,04|300|0,03|1.000|0,10|-|<small>[[QNG]]</small>}} | {{Tab Sp2-11 center|[[RB]]|450|45|0,10|0,04|300|0,03|1.000|0,10|-|<small>[[QNG]]</small>}} | ||
|- | |- | ||
Zeile 31: | Zeile 31: | ||
|- | |- | ||
{{Tab Sp2-11 center|[[SOLITEX ADHERO 1000]] | {{Tab Sp2-11 center|[[SOLITEX ADHERO 1000]] | ||
|327|180|0,55|0,04|545|0,3|545|0,3| - |<small>CE, [[EN 13583]]/[[Hagelwiderstand|HW5]], [[Luftdichtheit|Ld1]], [[R12]] <br /> W1, Srt, [[UDB | |327|180|0,55|0,04|545|0,3|545|0,3| - |<small>CE, [[EN 13583]]/[[Hagelwiderstand|HW5]], [[Luftdichtheit|Ld1]], [[R12]] <br /> W1, Srt, [[UDB]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K2]] </small>}} | ||
{{Tab Sp2-11 center|[[SOLITEX ADHERO 3000]] | {{Tab Sp2-11 center|[[SOLITEX ADHERO 3000]] | ||
|343|240|0,7|0,04|570|0,4|570|0,4|0,3 - 0,8|<small>CE, [[EN 13583]]/[[Hagelwiderstand|HW5]], [[Luftdichtheit|Ld1]], [[R12]] <br /> W1, Srt, [[AgBB]], [[UDB | |343|240|0,7|0,04|570|0,4|570|0,4|0,3 - 0,8|<small>CE, [[EN 13583]]/[[Hagelwiderstand|HW5]], [[Luftdichtheit|Ld1]], [[R12]] <br /> W1, Srt, [[AgBB]], [[UDB]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K2]], [[QNG]] </small>}} | ||
{{Tab Sp2-11 center|[[SOLITEX ADHERO VISTO]] | {{Tab Sp2-11 center|[[SOLITEX ADHERO VISTO]] | ||
|323|210|0,35|0,04|8.570|3|8.570|3|-|<small>CE, [[EN 13583]]/[[Hagelwiderstand|HW5]], [[Luftdichtheit|Ld1]], [[R10]] <br /> W1, Srt, [[AgBB]], [[UDB | |323|210|0,35|0,04|8.570|3|8.570|3|-|<small>CE, [[EN 13583]]/[[Hagelwiderstand|HW5]], [[Luftdichtheit|Ld1]], [[R10]] <br /> W1, Srt, [[AgBB]], [[UDB]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K2]], [[QNG]] </small>}} | ||
{{Tab Sp2-11 center|[[SOLITEX MENTO 1000]]<br /> [[SOLITEX MENTO 1000 connect| ... 1000 connect]] | {{Tab Sp2-11 center|[[SOLITEX MENTO 1000]]<br /> [[SOLITEX MENTO 1000 connect| ... 1000 connect]] | ||
Zeile 43: | Zeile 43: | ||
{{Tab Sp2-11 center|[[SOLITEX MENTO 3000]]<br /> [[SOLITEX MENTO 3000 connect| ... 3000 connect]] | {{Tab Sp2-11 center|[[SOLITEX MENTO 3000]]<br /> [[SOLITEX MENTO 3000 connect| ... 3000 connect]] | ||
|333|150|0,45|0,04|110|0,05|220|0,10|-|<small>CE, [[Hagelwiderstand|HW5]], [[Luftdichtheit|Ld1]], W1, Srt <br /> [[Unterdach|UD1]], [[USB | |333|150|0,45|0,04|110|0,05|220|0,10|-|<small>CE, [[Hagelwiderstand|HW5]], [[Luftdichtheit|Ld1]], W1, Srt <br /> [[Unterdach|UD1]], [[USB]], [[UDB]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K2]], [[QNG]], ZVDH </small>}} | ||
{{Tab Sp2-11 center|[[SOLITEX MENTO 5000]]<br /> [[SOLITEX MENTO 5000 connect| ... 5000 connect]] | {{Tab Sp2-11 center|[[SOLITEX MENTO 5000]]<br /> [[SOLITEX MENTO 5000 connect| ... 5000 connect]] | ||
|307|215|0,7|0,04|71|0,05|143|0,10|-|<small>CE, [[Hagelwiderstand|HW5]], [[Luftdichtheit|Ld1]], W1, Srt <br /> [[Unterdach|UD1]], [[USB | |307|215|0,7|0,04|71|0,05|143|0,10|-|<small>CE, [[Hagelwiderstand|HW5]], [[Luftdichtheit|Ld1]], W1, Srt <br /> [[Unterdach|UD1]], [[USB]], [[UDB]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K2]], [[QNG]], ZVDH </small>}} | ||
{{Tab Sp2-11 center|[[SOLITEX MENTO PLUS]]<br /> [[SOLITEX MENTO PLUS connect| ... PLUS connect]] | {{Tab Sp2-11 center|[[SOLITEX MENTO PLUS]]<br /> [[SOLITEX MENTO PLUS connect| ... PLUS connect]] | ||
|292|175|0,6|0,04|83|0,05|167|0,10|-|<small>CE, [[Hagelwiderstand|HW5]], [[Luftdichtheit|Ld1]], W1, Srt <br /> [[USB | |292|175|0,6|0,04|83|0,05|167|0,10|-|<small>CE, [[Hagelwiderstand|HW5]], [[Luftdichtheit|Ld1]], W1, Srt <br /> [[USB]], [[UDB]], [[Behelfsdeckung|Bhd]], [[Durchsturzsicherheit|D1]], [[Kaltbiegeverhalten|K2]] </small>}} | ||
{{Tab Sp2-11 center|[[SOLITEX MENTO ULTRA]]<br /> [[SOLITEX MENTO ULTRA connect| ... ULTRA connect]] | {{Tab Sp2-11 center|[[SOLITEX MENTO ULTRA]]<br /> [[SOLITEX MENTO ULTRA connect| ... ULTRA connect]] | ||
|222|200|0,9|0,04|167|0,15|111|0,10|-|<small>CE, [[Hagelwiderstand|HW5]], [[Luftdichtheit|Ld2]], W1, Srt <br /> [[USB | |222|200|0,9|0,04|167|0,15|111|0,10|-|<small>CE, [[Hagelwiderstand|HW5]], [[Luftdichtheit|Ld2]], W1, Srt <br /> [[USB]], [[UDB]], [[Behelfsdeckung|Bhd]], [[Durchsturzsicherheit|D2]], [[Kaltbiegeverhalten|K2]] </small>}} | ||
{{Tab Sp2-11 center|[[SOLITEX QUANTHO 3000 connect]] | {{Tab Sp2-11 center|[[SOLITEX QUANTHO 3000 connect]] | ||
|330|230|0,7|0,04|230|0,16|230|0,16|-|<small>ETA/CE, [[EN 13583]]/[[Hagelwiderstand|HW5]], [[Luftdichtheit|Ld1]], W1, Srt, [[AgBB]] <br /> [[Unterdach|UD1]], [[USB | |330|230|0,7|0,04|230|0,16|230|0,16|-|<small>ETA/CE, [[EN 13583]]/[[Hagelwiderstand|HW5]], [[Luftdichtheit|Ld1]], W1, Srt, [[AgBB]] <br /> [[Unterdach|UD1]], [[USB]], [[UDB]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K2]] </small>}} | ||
{{Tab Sp2-11 center|[[SOLITEX UD]]<br /> [[SOLITEX UD connect]] | {{Tab Sp2-11 center|[[SOLITEX UD]]<br /> [[SOLITEX UD connect]] | ||
|290|145|0,5|0,04|160|0,06|200|0,10| 0,01 <sup>[[Feuchtevariabilität|feuchtevariabel]]</sup>|<small>CE, [[Luftdichtheit|Ld1]], W1, Srt <br /> [[Unterdach|UD1]], [[USB | |290|145|0,5|0,04|160|0,06|200|0,10| 0,01 <sup>[[Feuchtevariabilität|feuchtevariabel]]</sup>|<small>CE, [[Luftdichtheit|Ld1]], W1, Srt <br /> [[Unterdach|UD1]], [[USB]], [[UDB]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K2]] </small>}} | ||
{{Tab Sp2-11 center|[[SOLITEX PLUS]]<br /> [[SOLITEX PLUS connect]] | {{Tab Sp2-11 center|[[SOLITEX PLUS]]<br /> [[SOLITEX PLUS connect]] | ||
|310|170|0,55|0,04|145|0,06|182|0,10| <0,02 <sup>[[Feuchtevariabilität|feuchtevariabel]]</sup>|<small>CE, [[Luftdichtheit|Ld1]], W1, Srt <br /> [[USB | |310|170|0,55|0,04|145|0,06|182|0,10| <0,02 <sup>[[Feuchtevariabilität|feuchtevariabel]]</sup>|<small>CE, [[Luftdichtheit|Ld1]], W1, Srt <br /> [[USB]], [[UDB]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K2]], iab, bba </small>}} | ||
{{Tab Sp2-11 center|[[SOLITEX UM connect]] | {{Tab Sp2-11 center|[[SOLITEX UM connect]] | ||
Zeile 67: | Zeile 67: | ||
{{Tab Sp2-11 center|[[SOLITEX WELDANO]] & [[SOLITEX WELDANO-S|...-S]] | {{Tab Sp2-11 center|[[SOLITEX WELDANO]] & [[SOLITEX WELDANO-S|...-S]] | ||
|385|310|0,8|0,04|225|0,18|225|0,18|-|<small>CE, [[Luftdichtheit|Ld1]], W1, [[Unterdach|UD2]], [[UDB | |385|310|0,8|0,04|225|0,18|225|0,18|-|<small>CE, [[Luftdichtheit|Ld1]], W1, [[Unterdach|UD2]], [[UDB]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K1]] </small>}} | ||
{{Tab Sp2-11 center|[[SOLITEX WELDANO 3000]] & [[SOLITEX WELDANO-S 3000|...-S 3000]] | {{Tab Sp2-11 center|[[SOLITEX WELDANO 3000]] & [[SOLITEX WELDANO-S 3000|...-S 3000]] | ||
|415|330|0,8|0,04|225|0,18|225|0,18|-|<small>CE, [[Hagelwiderstand|HW5]], [[Luftdichtheit|Ld1]], W1(+), [[Unterdach|UD2]], [[UDB | |415|330|0,8|0,04|225|0,18|225|0,18|-|<small>CE, [[Hagelwiderstand|HW5]], [[Luftdichtheit|Ld1]], W1(+), [[Unterdach|UD2]], [[UDB]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K1]] </small>}} | ||
{{Tab Sp2-11 center|[[SOLITEX FRONTA PENTA]] <br /> [[SOLITEX FRONTA PENTA connect| ... connect]] | {{Tab Sp2-11 center|[[SOLITEX FRONTA PENTA]] <br /> [[SOLITEX FRONTA PENTA connect| ... connect]] | ||
Zeile 216: | Zeile 216: | ||
| [[Unterdach]] || UD1 || CH: erhöhte Beanspruchung <small>n. [[SIA 232|SIA 232/1]]</small> || || UD2 || CH: außerordentl. Beanspruchg - DE: einzelvertragl. Vereinbarg | | [[Unterdach]] || UD1 || CH: erhöhte Beanspruchung <small>n. [[SIA 232|SIA 232/1]]</small> || || UD2 || CH: außerordentl. Beanspruchg - DE: einzelvertragl. Vereinbarg | ||
|- | |- | ||
| [[Unterspannbahn]] || [[USB | | [[Unterspannbahn]] || [[USB]] || ''s. Link'' || || - || | ||
|- | |- | ||
| [[Unterdeckbahn]] || [[UDB | | [[Unterdeckbahn]] || [[UDB]] ||''s. Link'' || || [[UDB]] || ''s. Link'' | ||
|- | |- | ||
| Materialgarantie || ZVDH || colspan="2" | Materialgarantie hinterlegt beim [[ZVDH]] || - || | | Materialgarantie || ZVDH || colspan="2" | Materialgarantie hinterlegt beim [[ZVDH]] || - || |