47.977
Bearbeitungen
K |
K |
||
(4 dazwischenliegende Versionen desselben Benutzers werden nicht angezeigt) | |||
Zeile 40: | Zeile 40: | ||
{{Tab Sp2-11 center|[[SOLITEX MENTO 1000]]<br /> [[SOLITEX MENTO 1000 connect| ... 1000 connect]] | {{Tab Sp2-11 center|[[SOLITEX MENTO 1000]]<br /> [[SOLITEX MENTO 1000 connect| ... 1000 connect]] | ||
|288|115|0,4|0,04|125|0,05|250|0,10|-|<small>CE, [[Luftdichtheit|Ld1]], W1, Srt <br /> | |288|115|0,4|0,04|125|0,05|250|0,10|-|<small>CE, [[Luftdichtheit|Ld1]], W1, Srt <br /> [[Kaltbiegeverhalten|K2]], [[QNG]] </small>}} | ||
{{Tab Sp2-11 center|[[SOLITEX MENTO 3000]]<br /> [[SOLITEX MENTO 3000 connect| ... 3000 connect]] | {{Tab Sp2-11 center|[[SOLITEX MENTO 3000]]<br /> [[SOLITEX MENTO 3000 connect| ... 3000 connect]] | ||
Zeile 55: | Zeile 55: | ||
{{Tab Sp2-11 center|[[SOLITEX QUANTHO 3000 connect]] | {{Tab Sp2-11 center|[[SOLITEX QUANTHO 3000 connect]] | ||
|330|230|0,7|0,04|230|0,16|230|0,16|-|<small>ETA/CE, [[EN 13583]]/[[Hagelwiderstand|HW5]], [[Luftdichtheit|Ld1]], W1, Srt, [[AgBB]] <br /> UD1, [[USB]], [[UDB]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K2]] </small>}} | |330|230|0,7|0,04|230|0,16|230|0,16|-|<small>ETA/CE, [[EN 13583]]/[[Hagelwiderstand|HW5]], [[Luftdichtheit|Ld1]], W1, Srt, [[AgBB]] <br /> UD1, [[USB]], [[UDB]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K2]], [[QNG]]</small>}} | ||
{{Tab Sp2-11 center| | {{Tab Sp2-11 center| [[SOLITEX UD connect]] | ||
|290|145|0,5|0,04|160|0,06|200|0,10| 0,01 <sup>[[Feuchtevariabilität|feuchtevariabel]]</sup>|<small>CE, [[Luftdichtheit|Ld1]], W1, Srt <br /> UD1, [[USB]], [[UDB]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K2]] </small>}} | |290|145|0,5|0,04|160|0,06|200|0,10| 0,01 <sup>[[Feuchtevariabilität|feuchtevariabel]]</sup>|<small>CE, [[Luftdichtheit|Ld1]], W1, Srt <br /> UD1, [[USB]], [[UDB]], [[Behelfsdeckung|Bhd]], [[Kaltbiegeverhalten|K2]] </small>}} | ||
Zeile 158: | Zeile 158: | ||
|E|-| 335 / 350 <br /> 325 / 335 | 36 / 50 | 200 / 200 |<small>-40 bis +100</small> |<small>bestanden</small>| 4<br />(3)<sup>3)</sup> | > 4,5 }} | |E|-| 335 / 350 <br /> 325 / 335 | 36 / 50 | 200 / 200 |<small>-40 bis +100</small> |<small>bestanden</small>| 4<br />(3)<sup>3)</sup> | > 4,5 }} | ||
{{Tab Sp2-10 center| | {{Tab Sp2-10 center| [[SOLITEX UD connect]] | ||
|E|5.2| 270 / 220 <br /> 265 / 175 | 60 / 75 <br /> 50 / 70 | 160 / 190 |<small>-40 bis +100</small> |<small>bestanden</small>| 3 | > 2,5 }} | |E|5.2| 270 / 220 <br /> 265 / 175 | 60 / 75 <br /> 50 / 70 | 160 / 190 |<small>-40 bis +100</small> |<small>bestanden</small>| 3 | > 2,5 }} | ||
Zeile 238: | Zeile 238: | ||
| QNG Anforderungen || [[QNG]] || colspan="4" | Anhangdokument 3.1.3 "Schadstoffvermeidung in Baumaterialien": erfüllt, jeweils im System mit einem Verbindungsmittel (s. techn. Daten der Produktseite) | | QNG Anforderungen || [[QNG]] || colspan="4" | Anhangdokument 3.1.3 "Schadstoffvermeidung in Baumaterialien": erfüllt, jeweils im System mit einem Verbindungsmittel (s. techn. Daten der Produktseite) | ||
|- | |- | ||
| Sentinel | | Sentinel Holding Institut || [[SHI]] || colspan="4" | Anforderung an [[Wohngesundheit|wohngesunde]] Bauprojekte, gem. Prüfberichte vom [[eco-INSTITUT]]. <small>Siehe auch [[ECO COLL]], [[ORCON F]], [[UNI TAPE]], [[TESCON No.1]] und [[TESCON VANA]].</small> | ||
|- | |- | ||
| CE-Kennzeichnung || CE || width="125px" | vorhanden || || - || | | CE-Kennzeichnung || CE || width="125px" | vorhanden || || - || |