Technische Daten (SOLITEX UD): Unterschied zwischen den Versionen
Zur Navigation springen
Zur Suche springen
K (→Lieferform) |
|||
Zeile 38: | Zeile 38: | ||
{| cellpadding="3" cellspacing="0" rules="all" style="background: #ffffff; border: 2px solid #aaa;" | {| cellpadding="3" cellspacing="0" rules="all" style="background: #ffffff; border: 2px solid #aaa;" | ||
|- style="background:#DFECF3;" | |- style="background:#DFECF3;" | ||
! width=" | ! width="70" | Art.-Nr. | ||
! width=" | ! width="120" | EAN | ||
! width=" | ! width="75" | Länge | ||
! width=" | ! width="75" | Breite | ||
! width=" | ! width="75" | Fläche | ||
! width="50" | | ! width="50" | kg/VE | ||
! width=" | ! width="40" | VE | ||
! width=" | ! width="60" | VE/Pal. | ||
|- | |- | ||
{{TabLiefer2|10130|4026639010520|50 m|1,50 m|75 m²|12 kg|1|20}} | {{TabLiefer2|10130|4026639010520|50 m|1,50 m|75 m²|12 kg|1|20}} |
Version vom 28. September 2009, 16:01 Uhr
Materialaufbau
Material | Stoff |
---|---|
Vlies | Polypropylen-Mikrofaser |
Membran | TEEE, monolithisch |
Vlies | Polypropylen-Mikrofaser |
Technische Daten
Eigenschaft | Prüfnorm | Wert |
---|---|---|
Farbe | - | hellblau |
Flächengewicht | DIN EN 1849-2 | 140 g/m² |
Dicke | DIN EN 1849-2 | 0,50 mm |
Dampfdiffusionswiderstandszahl | DIN EN 12572 | 160 |
sd-Wert | DIN EN 12572 | < 0,08 m |
Wasserdichtheit | DIN EN 1928 | W1 bestanden |
Brandklasse | DIN EN 13501-1 | E |
Freibewitterung | - | 3 Monate |
Reißfestigkeit quer | DIN EN 12311-2 | ca. 200 N/50 mm |
Reißfestigkeit längs | DIN EN 12311-2 | ca. 270 N/50 mm |
Nagelausreißfestigkeit | DIN EN 12310-1 | > 130 N |
Temperaturbeständigkeit | - | -40° C bis +100° C |
Die pro clima SOLITEX UD trägt das CE-Kennzeichen nach DIN EN 13859-1.
Lieferform
Art.-Nr. | EAN | Länge | Breite | Fläche | kg/VE | VE | VE/Pal. |
---|---|---|---|---|---|---|---|
10130 | 4026639010520 | 50 m | 1,50 m | 75 m² | 12 kg | 1 | 20 |