Technische Daten - Übersicht: Unterschied zwischen den Versionen
K |
|||
Zeile 6: | Zeile 6: | ||
| width="155" valign="bottom"| | | width="155" valign="bottom"| | ||
| width="60" style="font-size:90%" align="center" valign="top"| '''[[Dichte|Dichte<sub> </sub>]]''' <br /> <br /> [~ kg/m³] | | width="60" style="font-size:90%" align="center" valign="top"| '''[[Dichte|Dichte<sub> </sub>]]''' <br /> <br /> [~ kg/m³] | ||
| width="45" style="font-size:90%" align="center" valign="top"| '''[[Flächengewicht|Flächen-gewicht<sub> </sub>]]''' <br /> [g/m²] | |||
| width="60" style="font-size:90%" align="center" valign="top"| '''[[Dicke|Dicke<sub> </sub>]]''' <br /> <br /> [mm] | | width="60" style="font-size:90%" align="center" valign="top"| '''[[Dicke|Dicke<sub> </sub>]]''' <br /> <br /> [mm] | ||
| width="60" style="font-size:90%" align="center" valign="top"| '''[[WLF|WLF λ<sub> </sub>]]''' <br /> <br /> [W/mK] | | width="60" style="font-size:90%" align="center" valign="top"| '''[[WLF|WLF λ<sub> </sub>]]''' <br /> <br /> [W/mK] | ||
Zeile 16: | Zeile 17: | ||
|- | |- | ||
|- class="hintergrundfarbe2" | |- class="hintergrundfarbe2" | ||
| colspan=" | | colspan="7" valign="bottom"| '''Luftdichtung innen''' || colspan="2" align="center" valign="top"| <sup>nach [[DIN 4108|DIN 4108-3]]</sup>|| align="center" valign="top"| <small>'''Nicht''' für das [[Glaser-Verfahren]]</small> || | ||
|- | |- | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[INTELLO]]<br />[[INTELLO PLUS]]|500<br />550|85<br />110|0,20|0,17|37.500|7,50|37.500|7,50|0,25 - >10,00|<sup>SHI</sup>}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[DB]]<br />[[DB+]]|600<br />625|180<br />185|0,23|0,13|10.000|2,30|10.000|2,30|0,60 - 4,00|-}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[INTESANA]] / [[INTESANA connect|... - connect]]|310|140|0,45|0,17|16.700|7,50|16.700|7,50|0,25 - >10,00|-}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[DA]] / [[DA connect|... - connect]]|320|130|0,46|0,17|5.000|2,30|5.000|2,30|-|-}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[DASATOP]]|280|90|0,25|0,17|6.400|1,60|6.400|1,60|0,05 - 2,00|-}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[SANTA DT]] / [[SANTA UT|UT]]|600|185|0,40|0,13|5.750|2,30|5.750|2,30|-|-}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[RB]]|600|45|0,30|0,13|100|0,03|333|0,10|-|-}} | ||
|- | |- | ||
|- class="hintergrundfarbe2" | |- class="hintergrundfarbe2" | ||
|colspan=" | |colspan="11"| '''Winddichtung außen''' | ||
|- | |- | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[SOLITEX MENTO 1000]]<br /> [[SOLITEX MENTO 1000 connect| ... MENTO 1000 connect]] |275|110|0,4|0,17|125|0,05|250|0,10|-|-}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[SOLITEX MENTO 3000]]<br /> [[SOLITEX MENTO 3000 connect| ... MENTO 3000 connect]] | ||
|280|0,5|0,17|< 200|< 0,10|200|0,10|-|-}} | |280|140|0,5|0,17|< 200|< 0,10|200|0,10|-|-}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[SOLITEX MENTO 5000]]<br /> [[SOLITEX MENTO 5000 connect| ... MENTO 5000 connect]] | ||
|300|0,7|0,17|< 143|< 0,10|143|0,10|-|-}} | |300|210|0,7|0,17|< 143|< 0,10|143|0,10|-|-}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[SOLITEX MENTO PLUS]]<br /> [[SOLITEX MENTO PLUS connect| ... MENTO PLUS connect]] | ||
|285|0,6|0,17|< 167|< 0,10|167|0,10|-|-}} | |285|170|0,6|0,17|< 167|< 0,10|167|0,10|-|-}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[SOLITEX UD]]<br /> [[SOLITEX UD connect]]|280|140|0,50|0,17|160|< 0,08|200|0,10|0,02 <sup>[[Feuchtevariabilität|feuchtevariabel]]</sup>|-}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[SOLITEX PLUS]]<br /> [[SOLITEX PLUS connect]]|310|170|0,55|0,17|145|< 0,08|182|0,10|0,02 <sup>[[Feuchtevariabilität|feuchtevariabel]]</sup>|-}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[SOLITEX UM connect]]|63|450|8|0,17|10|< 0,08|12,5|0,10|0,02 <sup>[[Feuchtevariabilität|feuchtevariabel]]</sup>|-}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[SOLITEX WA]]|222|100|0,45|0,17|22|0,01|222|0,10|-|-}} | ||
|} | |} | ||
::: *) Nach [[DIN EN ISO 12572]] und [[DIN 4108|DIN 4108-3]] ist für [[sd-Wert|s<sub>d</sub>-Werte]] < 0,10 m der Rechenwert 0,10 m einzusetzen. | ::: *) Nach [[DIN EN ISO 12572]] und [[DIN 4108|DIN 4108-3]] ist für [[sd-Wert|s<sub>d</sub>-Werte]] < 0,10 m der Rechenwert 0,10 m einzusetzen. | ||
Zeile 56: | Zeile 57: | ||
{{{TabH1/1}} | {{{TabH1/1}} | ||
| width="148" valign="bottom"| '''Luftdichtung innen''' | | width="148" valign="bottom"| '''Luftdichtung innen''' | ||
| width="35" style="font-size:90%" align="center" valign="top"| '''[[Baustoffklasse|Brand- verh.]]''' <br /> | | width="35" style="font-size:90%" align="center" valign="top"| '''[[Baustoffklasse|Brand- verh.]]''' <br /> | ||
| width="30" style="font-size:90%" align="center" valign="top"| '''Brand-kennz.''' <br /> <br /> n. '''[[VKF]]''' | | width="30" style="font-size:90%" align="center" valign="top"| '''Brand-kennz.''' <br /> <br /> n. '''[[VKF]]''' | ||
Zeile 68: | Zeile 68: | ||
| | | | ||
|- | |- | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[INTELLO]]|E|5.3|120 / 90 |50 / 45|60 / 60 |<small>-40 bis +80</small> |<small>bestanden</small>| - | - | <sup>CE, [[Luftdichtheit|Ld]]</sup>}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[INTELLO PLUS]]|E|5.3|350 / 290|15 / 15 |240 / 200 |<small>-40 bis +80</small> | <small>bestanden</small>| - | - |<sup>CE, [[Luftdichtheit|Ld]]</sup>}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[DB]]|E|-|>90 / >90 |5 / 5|>80 / >80 |<small>bis +40, <br /> dauerhaft</small>|<small>bestanden</small>| - | - |<sup>CE, [[Luftdichtheit|Ld]]</sup>}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[DB+]]|E|-|550 / 300 |5 / 5 |70 / 70 |<small>bis +40, <br /> dauerhaft</small>|<small>bestanden</small>| - | - |<sup>CE, [[Luftdichtheit|Ld]]</sup>}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[INTESANA]] / [[INTESANA connect|... - connect]]|E|-|250 / 170 |60 / 60 |120 / 120 |<small>-40 bis +80</small> |<small>bestanden</small>| 2 | > 2,5 |<sup>CE, [[Luftdichtheit|Ld]], W1, [[Wassersäule|Ws]], Srt</sup>}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[DA]] / [[DA connect|... - connect]]|E|-|230 / 190 |50 / 50 |90 / 90 |<small>-40 bis +100</small> |<small>bestanden</small>| 3 | > 2,5 |<sup>CE, [[Luftdichtheit|Ld]], W1, [[Wassersäule|Ws]]</sup>}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[DASATOP]]|E|-|195 / 105 |70 / 70 |110 / 105 |<small>-40 bis +80 </small>|<small>bestanden</small>| - | - |<sup>CE, [[Luftdichtheit|Ld]]</sup>}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[SANTA DT]]<br />[[SANTA UT]]|E|-|-|-|-|<small>bis +40, <br /> dauerhaft</small>|-|-| - |}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[RB]]|E|-|-|-|-|<small>-40 bis +100 |-|-| - |}} | ||
|- | |- | ||
|- class="hintergrundfarbe2" | |- class="hintergrundfarbe2" | ||
|colspan=" | |colspan="11"| '''Winddichtung außen''' | ||
|- | |- | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[SOLITEX MENTO 1000]]<br /> [[SOLITEX MENTO 1000 connect| ... MENTO 1000 connect]] | ||
|E|-|205 / 170 | 50 / 50|100 / 100 |<small>-40 bis +100</small> |<small>bestanden</small>| 3 | 10 |<small>CE, [[Luftdichtheit|Ld]], W1, Srt <br /> [[USB-A]], [[UDB-B]], [[Behelfsdeckung|Bhd]] </small>}} | |||
{{Tab Sp2- | {{Tab Sp2-11 center|[[SOLITEX MENTO 3000]]<br /> [[SOLITEX MENTO 3000 connect| ... MENTO 3000 connect]] | ||
|E|-|230 / 180 | 45 / 65|180 / 240 |<small>-40 bis +100</small> |<small>bestanden</small>| 4 | 10 |<small>CE, [[Luftdichtheit|Ld]], W1, Srt <br /> [[USB-A]], [[UDB-B]], [[Behelfsdeckung|Bhd]] </small>}} | |||
{{Tab Sp2- | {{Tab Sp2-11 center|[[SOLITEX MENTO 5000]]<br /> [[SOLITEX MENTO 5000 connect| ... MENTO 5000 connect]] | ||
|E|-|340 / 250 | 40 / 50|260 / 360 |<small>-40 bis +100</small> |<small>bestanden</small>| 6 | 10 |<small>CE,[[Luftdichtheit|Ld]], W1, Srt <br /> [[USB-A]], [[UDB-A]], [[Behelfsdeckung|Bhd]] </small>}} | |||
{{Tab Sp2- | {{Tab Sp2-11 center|[[SOLITEX MENTO PLUS]]<br /> [[SOLITEX MENTO PLUS connect| ... MENTO PLUS connect]] | ||
|E|-|470 / 310 | 20 / 20|430 / 310 |<small>-40 bis +100</small> |<small>bestanden</small>| 4 | > 2,5 |<small>CE, [[Luftdichtheit|Ld]], W1, Srt <br /> [[USB-A]], [[UDB-A]], [[Behelfsdeckung|Bhd]] </small>}} | |||
{{Tab Sp2- | {{Tab Sp2-11 center|[[SOLITEX UD]]<br /> [[SOLITEX UD connect]]|E|-|270 / 200 |45 / 60|130 / 130 |<small>-40 bis +100</small> |<small>bestanden</small>| 3 | > 2,5 |<small>CE, [[Luftdichtheit|Ld]], W1, Srt <br /> [[USB-A]], [[UDB-A]], [[Behelfsdeckung|Bhd]], [[Durchsturzsicherheit|D]] </small>}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[SOLITEX PLUS]]<br /> [[SOLITEX PLUS connect]]|E|-|485 / 350 |15 / 15 |>350 / >350 |<small>-40 bis +100</small> |<small>bestanden</small>| 3 | > 2,5 |<small>CE, [[Luftdichtheit|Ld]], W1, Srt <br /> [[USB-A]], [[UDB-A]], [[Behelfsdeckung|Bhd]], [[Durchsturzsicherheit|D]] </small>}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[SOLITEX UM connect]]|E|-|270 / 200 |45 / 60 |>130 / >130 |<small>-40 bis +100</small> |<small>bestanden</small>| 3 | > 2,5 |<small>CE, [[Luftdichtheit|Ld]], W1 </small>}} | ||
{{Tab Sp2- | {{Tab Sp2-11 center|[[SOLITEX WA]]|E|-|190 / 145 |80 / 85|145 / 110 |<small>-40 bis +100</small> |<small>bestanden</small>| 3 | - |<small>CE, W2 </small>}} | ||
|} | |} | ||
Version vom 20. Juni 2011, 11:35 Uhr
Übersicht technische Daten der pro clima Dichtungsbahnen
Dichte [~ kg/m³] |
Flächen-gewicht [g/m²] |
Dicke [mm] |
WLF λ [W/mK] |
µ [-] |
sd-Wert [m] |
µ Rechenwert* [-] |
sd-Wert Rechenwert* [m] |
sd-Wert feuchtevariabel [m] |
||
Luftdichtung innen | nach DIN 4108-3 | Nicht für das Glaser-Verfahren | ||||||||
INTELLO INTELLO PLUS |
500 550 |
85 110 |
0,20 | 0,17 | 37.500 | 7,50 | 37.500 | 7,50 | 0,25 - >10,00 | SHI |
DB DB+ |
600 625 |
180 185 |
0,23 | 0,13 | 10.000 | 2,30 | 10.000 | 2,30 | 0,60 - 4,00 | - |
INTESANA / ... - connect | 310 | 140 | 0,45 | 0,17 | 16.700 | 7,50 | 16.700 | 7,50 | 0,25 - >10,00 | - |
DA / ... - connect | 320 | 130 | 0,46 | 0,17 | 5.000 | 2,30 | 5.000 | 2,30 | - | - |
DASATOP | 280 | 90 | 0,25 | 0,17 | 6.400 | 1,60 | 6.400 | 1,60 | 0,05 - 2,00 | - |
SANTA DT / UT | 600 | 185 | 0,40 | 0,13 | 5.750 | 2,30 | 5.750 | 2,30 | - | - |
RB | 600 | 45 | 0,30 | 0,13 | 100 | 0,03 | 333 | 0,10 | - | - |
Winddichtung außen | ||||||||||
SOLITEX MENTO 1000 ... MENTO 1000 connect |
275 | 110 | 0,4 | 0,17 | 125 | 0,05 | 250 | 0,10 | - | - |
SOLITEX MENTO 3000 ... MENTO 3000 connect |
280 | 140 | 0,5 | 0,17 | < 200 | < 0,10 | 200 | 0,10 | - | - |
SOLITEX MENTO 5000 ... MENTO 5000 connect |
300 | 210 | 0,7 | 0,17 | < 143 | < 0,10 | 143 | 0,10 | - | - |
SOLITEX MENTO PLUS ... MENTO PLUS connect |
285 | 170 | 0,6 | 0,17 | < 167 | < 0,10 | 167 | 0,10 | - | - |
SOLITEX UD SOLITEX UD connect |
280 | 140 | 0,50 | 0,17 | 160 | < 0,08 | 200 | 0,10 | 0,02 feuchtevariabel | - |
SOLITEX PLUS SOLITEX PLUS connect |
310 | 170 | 0,55 | 0,17 | 145 | < 0,08 | 182 | 0,10 | 0,02 feuchtevariabel | - |
SOLITEX UM connect | 63 | 450 | 8 | 0,17 | 10 | < 0,08 | 12,5 | 0,10 | 0,02 feuchtevariabel | - |
SOLITEX WA | 222 | 100 | 0,45 | 0,17 | 22 | 0,01 | 222 | 0,10 | - | - |
- *) Nach DIN EN ISO 12572 und DIN 4108-3 ist für sd-Werte < 0,10 m der Rechenwert 0,10 m einzusetzen.
Legende: | Alle Bahnen: | Spezifische Wärmekapazität: 1 J/(kg x k) |
SHI: | entspricht Sentinel-Haus-Institut Anforderungen an wohngesunde Bauprojekte, gem. Prüfbericht-Nr 21320-1-3 vom eco-INSTITUT. |
Die in einer Berechnung nach dem Glaser-Verfahren ermittelten Tauwasser- und Verdunstungsmengen verbessern sich bei feuchtevariablen Dampfbrems- und Luftdichtungsbahnen in der Realität erheblich. Feuchtevariable sd-Werte halten die Konstruktionen trocken und sorgen für bauschadensfreie Bauteile. Im Winter werden hohe sd-Werte erreicht und verhindern so bauteilschädigenden Feuchteeintrag. Im Sommer kann der sd-Wert im Bedarfsfall stark sinken und ermöglicht so eine rasche Austrocknung von Feuchtigkeit aus dem Bauteil heraus. Dadurch werden höchste Sicherheiten auch bei unvorhergesehenem Feuchteeintrag erreicht.
Weitere Werte
Luftdichtung innen | Brand- verh. |
Brand-kennz. n. VKF |
Höchst-zugkraft [N/50 mm] längs / quer |
Dehnung [%] längs / quer |
Weiterreiß-widerstand [N] längs / quer |
Temp.- best. [°C] |
Altergs- best. |
Freibe-witterg. [Mon.] |
Wasser- säule [m] |
|
INTELLO | E | 5.3 | 120 / 90 | 50 / 45 | 60 / 60 | -40 bis +80 | bestanden | - | - | CE, Ld |
INTELLO PLUS | E | 5.3 | 350 / 290 | 15 / 15 | 240 / 200 | -40 bis +80 | bestanden | - | - | CE, Ld |
DB | E | - | >90 / >90 | 5 / 5 | >80 / >80 | bis +40, dauerhaft |
bestanden | - | - | CE, Ld |
DB+ | E | - | 550 / 300 | 5 / 5 | 70 / 70 | bis +40, dauerhaft |
bestanden | - | - | CE, Ld |
INTESANA / ... - connect | E | - | 250 / 170 | 60 / 60 | 120 / 120 | -40 bis +80 | bestanden | 2 | > 2,5 | CE, Ld, W1, Ws, Srt |
DA / ... - connect | E | - | 230 / 190 | 50 / 50 | 90 / 90 | -40 bis +100 | bestanden | 3 | > 2,5 | CE, Ld, W1, Ws |
DASATOP | E | - | 195 / 105 | 70 / 70 | 110 / 105 | -40 bis +80 | bestanden | - | - | CE, Ld |
SANTA DT SANTA UT |
E | - | - | - | - | bis +40, dauerhaft |
- | - | - | |
RB | E | - | - | - | - | -40 bis +100 | - | - | - | |
Winddichtung außen | ||||||||||
SOLITEX MENTO 1000 ... MENTO 1000 connect |
E | - | 205 / 170 | 50 / 50 | 100 / 100 | -40 bis +100 | bestanden | 3 | 10 | CE, Ld, W1, Srt USB-A, UDB-B, Bhd |
SOLITEX MENTO 3000 ... MENTO 3000 connect |
E | - | 230 / 180 | 45 / 65 | 180 / 240 | -40 bis +100 | bestanden | 4 | 10 | CE, Ld, W1, Srt USB-A, UDB-B, Bhd |
SOLITEX MENTO 5000 ... MENTO 5000 connect |
E | - | 340 / 250 | 40 / 50 | 260 / 360 | -40 bis +100 | bestanden | 6 | 10 | CE,Ld, W1, Srt USB-A, UDB-A, Bhd |
SOLITEX MENTO PLUS ... MENTO PLUS connect |
E | - | 470 / 310 | 20 / 20 | 430 / 310 | -40 bis +100 | bestanden | 4 | > 2,5 | CE, Ld, W1, Srt USB-A, UDB-A, Bhd |
SOLITEX UD SOLITEX UD connect |
E | - | 270 / 200 | 45 / 60 | 130 / 130 | -40 bis +100 | bestanden | 3 | > 2,5 | CE, Ld, W1, Srt USB-A, UDB-A, Bhd, D |
SOLITEX PLUS SOLITEX PLUS connect |
E | - | 485 / 350 | 15 / 15 | >350 / >350 | -40 bis +100 | bestanden | 3 | > 2,5 | CE, Ld, W1, Srt USB-A, UDB-A, Bhd, D |
SOLITEX UM connect | E | - | 270 / 200 | 45 / 60 | >130 / >130 | -40 bis +100 | bestanden | 3 | > 2,5 | CE, Ld, W1 |
SOLITEX WA | E | - | 190 / 145 | 80 / 85 | 145 / 110 | -40 bis +100 | bestanden | 3 | - | CE, W2 |
Legende | Legende | ||||
CE-Kennzeichnung | CE: | ja | |||
Luftdicht | Ld: | ja | |||
Wasserdichtheit | W1: | W1 bestanden | W2: | W2 bestanden, regensicher | |
Schlagregentest | Srt: | bestanden - gemäß: ZVDH | |||
Unterspannbahn | USB-A: | s. Link | USB-B: | hier nicht vorh. | |
Unterdeckbahn | UDB-A: | s. Link | UDB-B: | s. Link | |
Behelfsdeckung | Bhd: | geeignet | |||
Durchsturzsicherheit | D: | bestanden - gemäß: BG BAU |
Der Verweis auf die jeweils bezogenen Normen findet sich auf den jeweiligen Produktseiten unter "Technische Daten".
Luftdichtung innen:
Neubau, Ausbau:
INTELLO Familie •
DB+ •
Aufdach:
INTELLO X Familie •
DA,
- connect •
Anschluss-Streifen: INTELLO conneX
Sanierung: DASATOP •
DASAPLANO 0,01 connect •
INTELLO X,
-connect •
Rieselschutz:
RB
Winddichtung außen:
Unterdeck-/Unterspannbahn:
SOLITEX MENTO •
SOLITEX QUANTHO 3000 connect (verklebt) •
SOLITEX PLUS connect
für Blecheindeckung: SOLITEX UM connect •
selbstklebend:
SOLITEX ADHERO •
nahtgefügte Unterdeckung (UDB-eA): SOLITEX WELDANO • Fassaden: SOLITEX FRONTA
Verbindungsmittel:
Klebebänder: TESCON VANA, - INVIS, - No.1 • - RAPIC • DUPLEX • UNI TAPE •
Anschlusskleber: ORCON F, - CLASSIC, - MULTIBOND
Fenster- / Putzanschlüsse: CONTEGA-Familie (Fensterbox) •
Kanten: TESCON PROFECT, - PROFIL, •
Ecken: TESCON TANGO, - INCAV
Flüssigdichtung: AEROSANA VISCONN-System •
Absperrklebebänder: EXTOSEAL-Familie •
Nageldichtung: TESCON NAIDECK-Familie •
Primer: TESCON (S)PRIMER
Manschetten: Kabel: KAFLEX • Rohr: ROFLEX • Elektro-Installationen: INSTAABOX • STOPPA
Detaillösungen:
Pflaster: TESCON VANA patch • UNI TAPE XL •
Einblasstopfen: CLOX
Montagehilfen: DASATOP FIX, TESCON FIX
Übersichten: Neuheiten • Anwendungsmatrix • Konstruktionsdetails • Techn. Daten: Bahnen, Verbindungsmittel • Archiv